2N7000 N-channel MOSFET connection guide
2N7000 N-channel MOSFET TO-92 formed leads wiring guide with power, signal assignments, and bench checks.
TO-92 formed leads
3 contacts Current packageTape-and-reel code in NDS7002A/D p. 7.
Wire the common return and gate pull-down
RequiredKeep both supplies off. Connect source and both supply returns together. Fit a 100 kΩ resistor from G to S to define the off state when the gate jumper is open. Use an ESD-safe work area.
Bench checks
- Verify the flat-face lead order and that R2 connects to G and S. Set the load supply to 5 V with a 10 mA limit and the gate supply to 10 V with a 1 mA limit.
onsemi NDS7002A/D Rev. 11, pp. 1–3; onsemi 2N7000TA/D Rev. 1, pp. 1–2. The pull-down and limits are bench choices.
Connection scenarios
Switch a 5 V resistive load
Put a 1 kΩ, 0.25 W load resistor between the +5 V rail and D. Keep the source and both supply returns joined. Connect G to the common return for the off test, then move the gate jumper to the +10 V gate supply for the on test.
- Load supply
- Regulated +5 V
- R1.1
- Load return
- R1.2
- D (3)
- Gate
- 0 V or +10 V gate jumper
- G (2)
- R2.1
- Common 0 V
- S (1)
- Load supply return
- Gate supply return
- R2.2
Bench checks
- With the meter common at S, verify VGS is near 0 V for off and 10 V for on. D should read near 5 V with the gate low and close to 0 V with it high.
- The 1 kΩ load draws about 5 mA when on. If D stays low with G at 0 V, turn off power and verify the orientation and the D/S connections.
onsemi NDS7002A/D Rev. 11, pp. 1–3; onsemi 2N7000TA/D Rev. 1, pp. 1–2. This example uses a resistive load and the shared 10 V gate test point.
TO-92 formed leads wiring map
3 · D
Connect to the low side of the load in a low-side switch. The intrinsic body diode has its cathode here.
Models and documents
onsemi TO-92 cases 135AN and 135AR. The 2N7000BU and 2N7000TA order codes use a separate electrical table. The SOT-23 2N7002 and NDS7002A have a different lead map and their own ratings.
- 2N7000-D26Z
- Tape-and-reel code in NDS7002A/D p. 7.
- 2N7000-D74Z
- Ammo code in NDS7002A/D p. 7. Confirm the supplied lead form against the package drawing.
- 2N7000-D75Z
- Tape-and-reel code in NDS7002A/D p. 7. Confirm the supplied lead form against the package drawing.
- 2N7000TA
- Fan-fold code in 2N7000TA/D.
- onsemi 2N7000 datasheet· NDS7002A/D · Rev. 11 · March 2025 · 2N7000 electrical column, ordering and both TO-92 outlines.
- onsemi 2N7000BU / 2N7000TA datasheet· 2N7000TA/D · Rev. 1 · July 2023 · Variant-specific ratings and ordering.
- Source register· Manufacturer URLs, applicability and file checksums.