DS3232 real-time clock connection guide
DS3232 real-time clock SO-20 · 300 mil wiring guide with power, signal assignments, and bench checks.
SO-20 · 300 mil
20 contacts Current package0 to +70 °C.
Connect an I²C host
RequiredConnect a 3 V primary cell to VBAT and connect all NC leads to ground. Leave 32kHz, INT/SQW and RST open if the host uses only the serial clock and calendar. The circuit ties both SCL pins together.
- +3.3 V
- VCC (4)
- Host 3.3 V
- C1.1
- R1.1
- R2.1
- Ground
- I²C data
- SDA (17)
- Host SDA
- R1.2
- I²C clock
- Backup supply
- VBAT (16)
- BT1+
Bench checks
- With VCC above the power-fail threshold, find 0x68 and read registers 0x00–0x06.
- Set a known time and clear the oscillator-stop flag in status register 0x0F after confirming that the oscillator is running.
- Remove main power briefly, then restore it and confirm that the clock advanced.
Analog Devices / Maxim DS3232 datasheet, electrical characteristics, pin description, and typical operating circuit.
SO-20 · 300 mil wiring map
15 · GND
Connect to the common ground plane or bench return.
Models and documents
This map covers the 20-lead wide SO package. Pins 18 and 20 both carry SCL. Connect either one or both to the same net.
- DS3232S#
- 0 to +70 °C.
- DS3232SN#
- −40 to +85 °C.
- DS3232 manufacturer documentation· Analog Devices / Maxim DS3232 datasheet, electrical characteristics, pin description, and typical operating circuit.