EC11E quadrature rotary encoder connection guide
EC11E quadrature rotary encoder EC11E without push switch wiring guide with power, signal assignments, and bench checks.
EC11E without push switch
5 contacts Current packageEC11E with push switch 5 contacts
30 detents, 15 pulses per revolution, no push switch.
Observe the two rotation phases
RequiredUse 5 V-tolerant inputs. Connect C to ground and fit one 4.7 kΩ pull-up and one 10 nF capacitor on each phase. Turn the shaft slowly while monitoring both lines.
- 5 V logic
- Regulated 5 V
- RA.1
- RB.1
- Ground
- C (C)
- Controller ground
- CA.2
- CB.2
- Phase A
- A (A)
- Controller input A
- RA.2
- CA.1
- Phase B
- B (B)
- Controller input B
- RB.2
- CB.1
Bench checks
- When closed, each contact carries about 1.06 mA. The closed phase should read near ground.
- Check the transition order in both directions. Contact bounce is much longer than the RC time constant, so debounce or reject invalid transitions in firmware.
Alps Alpine EC11E catalog, drawings 1–3, Output Wave and Cautions. Pull-ups are chosen to meet the minimum specified contact current.
EC11E without push switch wiring map
EC11E without push switch
A · A
Phase A switch contact. Pull up through an external resistor.
Models and documents
These maps cover the flat-shaft EC11E variants listed by Alps Alpine. The drawings identify mechanical support tabs and dummy terminals separately.
- EC11E09204A4
- 18 detents, 9 pulses per revolution, no push switch.
- EC11E15204A3
- 30 detents, 15 pulses per revolution, no push switch.
- EC11E1820402
- 36 detents, 18 pulses per revolution, no push switch.
- Alps Alpine EC11E catalog, drawings 1–3· Drawings, model table, output phase and application notes.