EMW3165 embedded Wi-Fi module connection guide
EMW3165 embedded Wi-Fi module EMW3165 family, 41 contacts wiring guide with power, signal assignments, and bench checks.
EMW3165 family, 41 contacts
41 contacts Current packageModule with IPEX external antenna connector.
Query the installed AT firmware
RequiredWire all supply and ground contacts and the crossed user UART. Use a 3.3 V serial adapter. For normal startup leave BOOT and STATUS open or use the manufacturer reference pull-ups.
- 3.3 V supply
- VBAT (10)
- VDD (39)
- VDD (40)
- Regulated 3.3 V
- C1.1
- C2.1
- Ground
- GND (20)
- GND (21)
- Supply return
- Host ground
- C1.2
- C2.2
- Host to module
- PA10 (29)
- Host UART TX
- Module to host
- PB6 (30)
- Host UART RX
Bench checks
- Check 3.3 V at all three power pads during startup. Keep the EMW3165 antenna clearance from Figure 4.
- Start at 115200 bit/s, 8N1. Send AT+FWVER? followed by CR in AT mode and check for a firmware version response.
- If the module is in transparent mode, use the documented +++ transition before querying. The debug UART on pads 8 and 12 is a separate port.
MXCHIP EMW3165 DS0007C v2.2, Figure 5 and Table 1; MXCHIP AT command firmware guide, Modes and Factory settings.
EMW3165 family, 41 contacts wiring map
EMW3165 family, 41 contacts
22 · NC
No application connection. Leave open.
Models and documents
The 41-contact layout follows the MXCHIP DS0007C v2.2 module drawing. The EMW3165 uses a PCB antenna and EMW3165-E has an IPEX connector. The UART test assumes the vendor AT firmware.
- EMW3165
- Default module with PCB antenna.
- EMW3165-E
- Module with IPEX external antenna connector.
- MXCHIP EMW3165 DS0007C v2.2· Manufacturer module drawing, terminal table, antenna variants and reference bypassing.
- MXCHIP AT command firmware guide· Manufacturer firmware startup straps, UART configuration, AT query and transparent-mode exit.