ICL7660 inverting charge pump connection guide
ICL7660 inverting charge pump PDIP-8 wiring guide with power, signal assignments, and bench checks.
PDIP-8
8 contacts Current packageSOIC-8 8 contacts
1.5 to 10 V operating supply, 0 to 70 °C.
Invert a 5 V rail
RequiredFit two 10 µF capacitors rated for at least 10 V. Leave NC, LV and OSC open at 5 V.
- Positive supply
- V+ (8)
- Current-limited 5 V supply
- Ground
- GND (3)
- C2 positive
- Supply return
- Meter common
- Flying capacitor positive
- CAP+ (2)
- C1 positive
- Flying capacitor negative
- CAP− (4)
- C1 negative
- Negative output
- VOUT (5)
- C2 negative
- Meter positive
Bench checks
- Check the polarized capacitor orientation. C1 positive goes to CAP+ and C2 positive goes to ground.
- Read VOUT with respect to ground on a high-impedance meter. Expect a negative voltage approaching −5 V without a load.
Renesas / Intersil FN3072 Rev. 7.00, Figure 13 and Do’s And Don’ts.
Connection scenarios
Measure the output drop under load
Turn power off and add a 10 kΩ resistor from VOUT to ground. Use the same supply and capacitors.
- Positive supply
- V+ (8)
- Current-limited 5 V supply
- Ground
- GND (3)
- C2 positive
- Supply return
- Meter common
- RL.1
- Flying capacitor positive
- CAP+ (2)
- C1 positive
- Flying capacitor negative
- CAP− (4)
- C1 negative
- Negative output
- VOUT (5)
- C2 negative
- Meter positive
- RL.2
Bench checks
- Expect a nominal load of about 0.5 mA. Compare the loaded voltage and ripple against the unloaded reading.
Renesas / Intersil FN3072 Rev. 7.00, Figures 13–14. The load is a fixture choice.
PDIP-8 wiring map
7 · OSC
Leave open to use the internal oscillator unmodified.
Models and documents
The original ICL7660 and ICL7660A share the same contact functions. The ICL7660S has a frequency boost pin where this map shows NC.
- ICL7660CPA
- 1.5 to 10 V operating supply, 0 to 70 °C.
- ICL7660CPAZ
- 1.5 to 10 V operating supply, 0 to 70 °C.
- ICL7660ACPA
- 1.5 to 12 V operating supply, 0 to 70 °C.
- ICL7660ACPAZ
- 1.5 to 12 V operating supply, 0 to 70 °C.
- Renesas / Intersil FN3072 Rev. 7.00· Ordering guide, pin map and simple negative converter.
- Source register· Document revisions, applicable order codes, consulted sections and available file checksums.