Spark Logic

BH1750 ambient light sensor pinout

The BH1750FVI is a digital ambient-light sensor with a 16-bit illuminance result. DVI sets the I²C reference and controls power-on reset.

WSOF-6I

7 contacts Current package

ROHM ·

WSOF-6I pinout

Top view. Start at the package pin-1 index and follow the numbered leads.
EP is the exposed center pad on the underside.
Selected pin details

4 · SDA

Bidirectional · Bidirectional

Open-drain I²C data. The bus needs a pull-up to its logic rail.

ROHM BH1750FVI Technical Note, Rev. D (November 2011), pp. 2, 6–10, 13 and 16–17. Manufacturer PDF hosted by Mouser.

Electrical limits · Link to this pin

All 7 pins

PinSignalDirectionFunction
1VCC Supply inputSupply input Primary device supply. Place the bypass capacitor close to this pin.
2ADDR InputInput Low selects 0x23. High selects 0x5C. Do not leave this terminal floating.
3GND Supply returnSupply return Connect to the common ground plane or bench return.
4SDA BidirectionalBidirectional Open-drain I²C data. The bus needs a pull-up to its logic rail.
5DVI Reference inputReference input I²C reference and active-low asynchronous reset. Hold at or below 0.4 V for at least 1 µs after VCC is supplied.
6SCL InputInput I²C clock. Connect to the host clock line with its bus pull-up.
7Exposed pad Leave openLeave open Do not solder or electrically connect the exposed underside pad.

Signal assignments

I²C

Select 0x23 or 0x5C using ADDR. Send one command per write transaction. Read the result as two bytes, most significant byte first.

Electrical limits

ParameterLimitConditions and source
Main supply VCC2.4–3.6 V2.4–3.6 V Bare IC operating range. ROHM BH1750FVI Technical Note, Rev. D (November 2011), pp. 2, 6–10, 13 and 16–17. Manufacturer PDF hosted by Mouser.
DVI reset≤0.4 V for ≥1 µs≤0.4 V for ≥1 µs Measured after VCC is supplied. DVI rises to the bus reference afterward. ROHM BH1750FVI Technical Note, Rev. D (November 2011), pp. 2, 6–10, 13 and 16–17. Manufacturer PDF hosted by Mouser.
High-resolution mode120 ms typical · 180 ms maximum120 ms typical · 180 ms maximum At the default measurement-time register setting. ROHM BH1750FVI Technical Note, Rev. D (November 2011), pp. 2, 6–10, 13 and 16–17. Manufacturer PDF hosted by Mouser.

Models and documents

The map applies to the bare BH1750FVI. Breakout modules may supply DVI from separate circuitry.

BH1750FVI-TR
WSOF-6I, tape and reel.