Spark Logic

DSO138 oscilloscope pinout

The DSO138 is a single-channel digital oscilloscope kit with a BNC input and an onboard square-wave output for probe compensation.

DSO138 13803K / 13804K

7 contacts Current package

JYE Tech · JYE Tech kit connectors for the BNC input, DC supply and test signal.

DSO138 13803K / 13804K pinout

J1 BNC input
Viewed into the input socket. The center is the signal.
J10 DC barrel jack
Viewed into the DC jack. The center is positive. J10 is beside the power header on the PCB.
J9 alternate DC header
PCB pin numbers from the schematic. Use one power entry at a time.
J2 test output
One exposed test contact. Both PCB pads of the terminal carry the same signal.
Selected pin details

J10 sleeve · DC_RETURN

Supply return · Ground

Outer sleeve of the barrel jack.

JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4.

Electrical limits · Link to this pin

All 7 pins

PinSignalDirectionFunction
J1 centerAIN Analog inputAnalog input Connect the probe tip to the measured signal.
J1 shellAGND Analog returnAnalog return Connect the probe ground clip to the circuit’s common return.
J10 centerDC_IN Supply inputSupply input Positive contact of the 5.5 × 2.1 mm barrel jack.
J10 sleeveDC_RETURN Supply returnSupply return Outer sleeve of the barrel jack.
J9-1DC_IN Supply inputSupply input Positive contact of the alternate PCB power header.
J9-2DC_RETURN Supply returnSupply return Ground contact of the alternate PCB power header.
J2TESTSIG Square-wave outputSquare-wave output Onboard 1 kHz, 3.3 V square wave.

Signal assignments

Probe compensation output

Use the scope’s own probe and test contact for compensation.

Electrical limits

ParameterLimitConditions and source
DC supply9 V nominal, 8–12 V allowed9 V nominal, 8–12 V allowed Center positive. Use a regulated supply rated above 200 mA. JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4.
Analog input1 MΩ / 20 pF1 MΩ / 20 pF BNC input with the manufacturer’s specified input impedance. JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4.
Maximum input50 V peak with a ×1 probe50 V peak with a ×1 probe Manufacturer’s limit. The wiring example uses a loose 1.5 V cell. JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4.
Analog bandwidth and maximum sample rate200 kHz, 1 MSa/s200 kHz, 1 MSa/s The scope samples a single analog input. JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4.
Test output1 kHz, 3.3 V1 kHz, 3.3 V Built-in square wave on J2. JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4.

Models and documents

This map covers original JYE Tech kits 13803K and 13804K. The optional J4 Mini-USB footprint is listed without a user function. Use J10 or J9 for power.

DSO138 13803K / 13804K
JYE Tech kit connectors for the BNC input, DC supply and test signal.