Single-ended BNC input
The displayed voltage is the center contact relative to the BNC shell.
The DSO138 is a single-channel digital oscilloscope kit with a BNC input and an onboard square-wave output for probe compensation.
Positive contact of the alternate PCB power header.
| Pin | Signal | Direction | Function |
|---|---|---|---|
| J1 center | AIN Analog input | Analog input | Connect the probe tip to the measured signal. |
| J1 shell | AGND Analog return | Analog return | Connect the probe ground clip to the circuit’s common return. |
| J10 center | DC_IN Supply input | Supply input | Positive contact of the 5.5 × 2.1 mm barrel jack. |
| J10 sleeve | DC_RETURN Supply return | Supply return | Outer sleeve of the barrel jack. |
| J9-1 | DC_IN Supply input | Supply input | Positive contact of the alternate PCB power header. |
| J9-2 | DC_RETURN Supply return | Supply return | Ground contact of the alternate PCB power header. |
| J2 | TESTSIG Square-wave output | Square-wave output | Onboard 1 kHz, 3.3 V square wave. |
The displayed voltage is the center contact relative to the BNC shell.
The barrel jack and the alternate two-pin header feed the same supply input.
Use the scope’s own probe and test contact for compensation.
| Parameter | Limit | Conditions and source |
|---|---|---|
| DC supply9 V nominal, 8–12 V allowed | 9 V nominal, 8–12 V allowed | Center positive. Use a regulated supply rated above 200 mA. JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4. |
| Analog input1 MΩ / 20 pF | 1 MΩ / 20 pF | BNC input with the manufacturer’s specified input impedance. JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4. |
| Maximum input50 V peak with a ×1 probe | 50 V peak with a ×1 probe | Manufacturer’s limit. The wiring example uses a loose 1.5 V cell. JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4. |
| Analog bandwidth and maximum sample rate200 kHz, 1 MSa/s | 200 kHz, 1 MSa/s | The scope samples a single analog input. JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4. |
| Test output1 kHz, 3.3 V | 1 kHz, 3.3 V | Built-in square wave on J2. JYE Tech DN138-01v05, Operation and Probe Calibration on p. 3 and schematic on p. 4. |
This map covers original JYE Tech kits 13803K and 13804K. The optional J4 Mini-USB footprint is listed without a user function. Use J10 or J9 for power.